scxi-1162hv. Add to Cart. scxi-1162hv

 
 Add to Cartscxi-1162hv  Each channel also includes a

Website: GE General Electric. The resulting reduction in the number of submarine assets and supporting maintenance dollars jeopardize the Navy’s ability to complete their complex mission requirements. SCXI-1162HV User Manual - National Instruments. I'm inputting three 120VAC signals to one bank of an SCXI-1162HV board via a TBX-1326 terminal. National Instruments will, at its option, repair or National Instruments SCXI-1162HV 32-Channel Isolated Digital Input Module Part Number: 182638-01, 182638C-01, 182638D-01, 182638E-01, 185628C-01, 182628E-01 Show More Description Re: PXIe-6361 does not recognize SCXI modules on SCXI-1000. SCXI-1540 using Measurement & Automation Explorer or through function calls to NI-DAQ. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. You cable the TBX-1326 to the SCXI module with the SH48-48-B shielded cable. The TBX-1326 is a DIN-rail mountable terminal block that connects to an SCXI module front connector with an SH48-48-B cable. 操作系统支持. Welcome to J316Gallery. info and type rdfis5 to order a configured PXI/SCXI combination chassis. The NI DAQ driver software can be executed for operating the SCXI-1162HV. SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B Ð High-voltage 250 VDC TBX-1328 SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126 SH32-32-A Sockets for current. I use the digital data logger to log the input from lines 4 and 7 and the digital da. The 16 DC outputs were controlled with an SCXI-1163R. This Terminal Block is also well-suited for. com. ) Figure 3. SCXI-1162HV User Manual - National Instruments. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. For example, you can use an SCXI-1162HV to sense the on/off state of power circuits, proximity switches, pushbutton switches, thermostats, or relays. SCXI-1163, 32-Channel, Digital I/O Module Get Quote SCXI-1163R. This module senses the presence of a wide range. 1 1 (32-bit and 64-bit); Windows 7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2, SP1 (32-bit and 64-bit); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1, SP1 (64-bit, not supported on. This module senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals. . NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1163R 32-channel solid state relay; NI SCXI-1520 strain gage input module; NI SCXI-1530 and. National Instruments SCXI-1128 Matrix/Multiplexer Switch Module- 9 W maximum switching power. 0/8. Support Worldwide Technical Support and Product Information ni. 2를 설치합니다. NI-DAQmx 17. NI-DAQmx is the software you use to communicate with and control your NI data acquisition (DAQ) device. 4 days ago. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. SCXI-1162HV User Manual - National Instruments. Each SCXI chassis contains an 1162HV module for reading high voltage digital signals and an 1102 thermocouple module connected to a 6251 M Series MIO DAQ card to read up to 32. I am trying to wire an SCXI-1162HV module and I want to make sure it can handle my input. 1 1 /7 SP1 2 (32-bit and 64-bit) Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers) Windows Server 2012 R2 1 (64-bit) Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role) 1 NI software installs VC2015 Runtime and . Find the National Instruments SCXI-1328 at our website: Click HERE. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. EN. MOORE AUTOMATION LIMITED Surel miya@mvme. Windows 8. SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient. Table of Contents. for 1324. Each SCXI chassis contains an 1162HV module for reading high voltage digital signals and an 1102 thermocouple module connected to a 6251 M Series MIO DAQ card to read up to 32 thermocouples. 1 addresses an issue in which incorrect data is returned by multi-device tasks run on the NI cDAQ-9179 with specific module configurations. 1的支持。. 0及后续版本无法在不支持的操作系统上安装或运行。. SCXI-1162HV PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, INPUT MODULE, DIGITAL 32 CHANNEL, HIGH VOLTAGE ISOLATED, 240 VAC/DC, DIGITAL, PROGRAMMED BY THE DAQ DEVICE SERIALLY OVER THE SCXIBUS The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. Mobile/ WeChat/ WhatsApp:+86 13365909307. arincTBX-1326 high-voltage terminal block with the SCXI-1162/HV, SCXI-1163, and SCXI-1163R modules. 5; LabVIEW: 2015, 2016, 2017, and 2018: LabVIEW Real-Time Module: 2015, 2016, 2017, and 2018: LabVIEW NXGGet the best deals for scxi-1162 at eBay. Does NI have a PXI equivalent to the SCXI-1162SCXI-1162HV User Manual - National Instruments. Supported Operating Systems. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. NI-DAQmx Readme Updates. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. SCXI-1162HV NI module, NI, SCXI-1162HV NI module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States4 days ago. It sounds like your 1162HV is working correctly. The SCXI-1162HV is designed for 240 VAC/VDC input. 1 No connects appear on pins 20 through 22 of devices that do not support AO or use an external reference. SCXI, switches ; Multiplexer / switch matrix ; SCXI-1127 ; Solid state relays ; SCXI-1163R ; General purpose ;This file contains important information about NI-DAQmx, including installation instructions and known issues. La utilería convierte chasis SCXI, módulos y bloques terminales soportados por NI-DAQmx. 1(32位和64位). This Terminal Block is also well-suited for. com. NI DAQCard 6024E 200 kS/s, 12-bit, 16 AI channel, two AO channel, 8 DIO line, two counter/timer device. (SSK 876) HMCS Victoria is a long-range hunter-killer (SSK) submarine of the Royal Canadian Navy, the lead ship of her class. FIM card MOOG — D136-001-007 Servo valve, controller, module NI — SCXI-1100 PCI – PXIE – PCIE – SBRIO – CFP-AO-210 USB-6525 Information Acquisition Card, PXI Module,. Set the SCXI chassis address switch positions to the desired address. 0: Windows 10/8. During steady-state experiments, SCXI channels are written to memory tags, while in transient tests (where. The SCXI-1162HV Digital I/O Module can monitor TTL level inputs and sense the existence of high-voltage AC and DC signals. National Instruments SCXI-1326 SCXI Terminal Block Manuals, Datasheets, Drivers, Links. The optical isolation of the SCXI‑1162HV eliminates ground. SCXI-1162HV User Manual - National Instruments. . 531X304IBDARG1 F31X304IBDAMG1–00609. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Supported Operating Systems. cabled device : nil. Supported Operating Systems. The terminal block has 48 screw terminals for easy signal connections. The SCXI 1162HV optically isolated digital input module is used to know the status of the Scanivalve multiplexer and the wafer switches. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. The best choice for this health monitoring system was a combination PXI/SCXI chassis due to its compactness and high density of instrumentation. The TBX-1326 mounts on most European standard DIN EN mounting rails. Digital Input Number of channels. . 0 para Win95. The best choice for this health monitoring system was a combination PXI/SCXI chassis due to its compactness and high density of instrumentation. Windows 10/8. · scxi-1162hv: 设置跳线 w3 到p位置--注意:如果连接到mio板卡, 设置跳线 w2 到mio位置. NI-DAQmx 15. Well, my question is how i can control this scxi 1001 device. Ce fichier contient des informations importantes relatives à NI-DAQmx, notamment les instructions d'installation et les problèmes connus. Supported Operating Systems. Product Parameters: Voltage. 1 1 /7 SP1 2 (32-bit and 64-bit 3); Windows Embedded Standard 7 2, SP1 (on Compact DAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1, SP1 (64-bit, not supported on Server Core Role); 1 NI. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. The. The terminal block has 48 screw terminals for easy signal connections. 2. The SCXI-1326 is high-voltage and has 48 screw terminals for signal connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. The neutral is at earth ground potential. 2. Windows Vista商用版、Service. Website: GE General. HMCS. National Instruments SCXI-1162HV User Manual (43 pages) 32-Channel Isolated AC/DC Digital Input Module. It allows for. . 1 Readme. Windows Server 2008 R2 P1(64ビット、サーバコアロールでは. All prices are shown in USD. Brand: National Instruments | Category: I/O Systems | Size: 0. The. The SCXI 1162HV has 32 channels of optically—isolated digital inputs, arranged into eight isolated banks of four input lines each. NI-DAQmx软件可与NI数据采集 (DAQ)设备通信并控制设备。. NI DAQCard-6024E 200 kS/s, 12-bit, 16 AI channel, two AO channel, 8 DIO line, two counter/timer device;. Does NI have a PXI equivalent to the SCXI-1162SCXI-1162HV User Manual - National Instruments. NI-DAQmx 16. Read this document to learn how to use NI. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. The National Instruments SCXI-1326 is designed for high-voltage digital input or digital output applications. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-0132-Channel, Input (240 V), Digital I/O Module for SCXI. ⑥ Does it include tariffs? It does not include any. SCXI-1162HV User Manual - National Instruments. Quarter-Bridge Configurations. 4-12. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. I know the inputs are tied together. Default NI-DAQmx Counter Terminals. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. The National Instruments TBX-1326 is a high-voltage terminal block with 48 screw terminals for the SCXI-1162 Series and SCXI-1163 Series modules. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. The following operating systems are supported by NI-DAQmx 17. This Digital I/O Module senses the existence of a variety of AC or DC signals. sales@changxinplc. The target and host are running LV Real-Time 8. ni scxi-1600 usb模块 重要通知:用于USB DAQ设备和Windows XP的Microsoft修补程序 如在Windows XP平台上使用USB DAQ设备和NI-DAQmx,建议安装 知识库文章969238 中的Microsoft修补程序。SCXI-1162HV User Manual - National Instruments. La aplicación usaba la función WriteToDigitalLine() con el archivo de configuración. ·. You are using an SCXI-1530, SCXI-1531, or SCXI-1540 device with accelerometer, linear-voltage differential transformer (LVDT), or rotary variable-differential transformer (RVDT) virtual channels, which are not supported by NI-DAQmx. Refer to the NI website for any updates to the current NI-DAQmx readme. . NET 4. E-mail: simondcsplc@foxmail. Getting Started with SCXI - National Instruments. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 4-10 Figure 4-5. 自本版本起,NI-DAQmx不再支持Microsoft Windows 7 RTM(无service pack)、Windows Vista、Windows XP和Windows Server 2003。. ¹When the module is plugged into J17, when plugged into J18, the DAC output channels are reversed. The optical isolation also alienates the host device from damaging voltages. 1 1 /7 SP1 2 (32-bit 3 and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI. . E-mail: simondcsplc@foxmail. उच्च गुणवत्ता NI SCXI-1000 SCXI-1162HV SCXI-1180 SCXI-1163R 1302/1326 * मूल * चीन से, चीन का अग्रणी dcs स्वचालन उत्पाद, सख्त गुणवत्ता नियंत्रण के साथ dcs मॉड्यूल कारखानों, उच्च गुणवत्ता का. This scxi 1001 has 5x scxi 1163R modules and 2x scxi 1162HV modules. The National Instruments SCXI-1162HV is an optically-isolated digital input module. The optical isolation of the SCXI-1162 and SCXI-1162HV eliminates ground-loop problems and isolates the host computer from damaging voltages. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. 18 MB. ni scxi-1600 usb模块 重要通知:用于USB DAQ设备和Windows XP的Microsoft修补程序 如在Windows XP平台上使用USB DAQ设备和NI-DAQmx,建议安装 Microsoft知识库文章969238 中的Microsoft修补程序。The SCXI-1326 is high-voltage and has 48 screw terminals for signal connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. This warranty includes parts and labor. National Instruments SCXI-1326 SCXI Terminal Block Manuals, Datasheets, Drivers, Links. 4-12. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. NI-DAQmx 17. If a sample rate is set fast enough to require a convert clock rate greater than the default rate, warning 200011 is generated, informing the user that the accuracy of the. The SCXI-1162HV is a module for sensing the presence of AC or DC voltages where high common-mode voltages may be present. SCXI-1162HV User Manual - National Instruments. In Figure 4, all switches are shown in the off position. TBX-1326 SCXI-1162, SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B – High-voltage 250 VDC TBX-1326 high-voltage terminal block with the SCXI-1162/HV, SCXI-1163, and SCXI-1163R modules. 1 Readme. 0은 다음 OS를 지원합니다. NI Software Support for Microsoft Windows 7, Windows Vista, Windows XP, and Windows Server 2003. It has isolated input channels with 300 Vrms working isolation as well 12 programmable gain settings. Add to Quote. The following operating systems are supported by NI-DAQmx 18. You can cable the TBX-1326 to the SCXI module with the SH48-48-B shielded cable. Quarter-Bridge Configurations. SCXI-1162HV NI 32-Channel, Isolated AC/DC, Digital Input Module, NI, SCXI-1162HV NI 32-Channel, Isolated AC/DC, Digital Input Module The NI SCXI-1162HV (Part Number: 776572-62H) has 32 channels of optically-isolated digital inputs, which are organized into eight separate banks of four input lines each. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. 1553. SCXI-1162HV User Manual - National Instruments. 0では、以下のオペレーティングシステムがサポートされます。. Warning: The TBX-1326 and SH48-48-B limit the maximum working common-mode voltage between banks or between banks and earth ground to 250 V rms maximum. National Instruments SCXI-1162HV 32-Channel Isolated Digital Input ModulePart Number: 776572-62HPlease contact Artisan Technology Group Sales for pricing and availability. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. --. NI-DAQmx 17. She is named after the city of. This guide describes how to use and install the SCXI-1326 high-voltage terminal block with the SCXI-1162, the SCXI-1163, the SCXI-1162HV, and the SCXI-1163R modules. The problems facing with the modules are as follows. It is an ideal solution for large-channel-count temperature or voltage applications. PXI-6529: 48. Another type of SCXI module is digital input and output modules. 0 para Win95. SCXI-1162HV, 32-Channel, Isolated AC/DC, Digital Input Module Get Quote SCXI-1163. are not included with this equipment unless listed in the above stock item description. Driver Version Naming Changes. SCXI-1162, SCXI-1162HV Typical for 25 ûC unless otherwise noted. The SCXI-1162 and SCXI-1162HV safely isolate the computer from the large common-mode voltages, ground loops, and voltage spikes that often occur in industrial and research environments. . Änderungen an der Readme zu NI-DAQmx. 1 1 /7 SP1 2 (32-bit 3 and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI. Janvier 2019. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。Operating System Support. This module recognizes AC/DC signals from digital logic levels. 4-10 Figure 4-5. 1 running on XP machine, until we get new updated kit in future ( current NT machines are failing ). SCXI-1128. Important Information Warranty Your DAQ hardware is warranted against defects in materials and workmanship for a period of one year from the dateThe following operating systems are supported by NI-DAQmx 17. Esta se ha reconvertido con CVI 7. They will be in an SCXI Chassis controlled by an E-series DAQ card. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Mobile/ WeChat/ WhatsApp:+86 13365909307. SCXI-1125 with high-voltage attenuator ; NI-4060 DMM ; 24 Three-Phase Power Measurements. EN. SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient. Présentation générale. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. Supported Operating Systems. . SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. . The terminal block has 48 screw terminals for easy signal connections. Power off both the PXI and SCXI power switches, and unplug the chassis. 1. 8-Channel Frequency Input Module for SCXI—The SCXI‑1126 is an isolated frequency input module for SCXI. Recursos para Soporte del Producto. --. Systèmes d'exploitation supportés. The question is what is the best method for reading these four ports. MIO–16 Connector. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI-1162HV User Manual - National Instruments. National Instruments will, at its option, repair or scxi-1326 でvcc とラベル表示されている端子は、scxi-1162hv また はscxi-1163r と一緒に使用できません。gnd とラベル表示されている 端子は、scxi-1162 では使用しません。ネジ留め式端子は6 端子一組の合 計8 組が配置されています。各組ごとに絶縁されています。各. Share: Description Consultation price Reviews (0)SCXI Terminal Blocks Overview National Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. . NET 4. Supported Operating Systems. The terminals labeled GND are not used on the SCXI-1162. 1 1 /7 SP1 2 (32-bit and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI software installs. I've configured with MAX two channels the first is the channel to Dev1 port PA0, teh second is the channel to Dev1_SC1_MD1 DIN1. 32-Channel, Input (240 V), Digital I/O Module for SCXI. SCXI Model Number: PXI Model Number: C Series Model Number SCXI-1000: PXIe-1071: cDAQ 9174 cDAQ 9184 SCXI-1000DC: PXIe-1071 PXIe-1082 (782946-01) cDAQ 9174 cDAQ 9184: Choose the PXIe-1071 if the application requires four PXIe slots; however, if DC power is a more important feature choose the PXIe-1082 (DC). The terminal block has 48 screw terminals for easy signal connections. The TBX-1326 is a DIN-rail mountable terminal block that connects to an SCXI module front connector with an SH48-48-B cable. For High-Voltage Digital Input or Digital Output Applications. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. Application Software 1 Versions Supported by NI-DAQmx 18. ni scxi-1600 usb 모듈 중요한 알림 사항: USB DAQ 디바이스 및 Windows XP를 위한 Microsoft Hotfix Windows XP에서 USB DAQ 디바이스와 함께 NI-DAQmx를 사용하는 경우, Microsoft Knowledge Base 969238 의 설명과 같이. Mobile/ WeChat/ WhatsApp:+86 13365909307. NI SCXI-1162HV DIO module; NI SCXI-1163 DIO module; NI SCXI-1190 RF switch module; NI SCXI-1191 switch module; NI SCXI-1192 switch module;SCXI-1162HV. NI SCXI-1162 32通道高压数字输入模块 SCXI-1162HV 库存. ni scxi-1162hv; ni scxi-1163; ni scxi-1163r; ni scxi-1166; ni scxi-1167; ni scxi-1169; ni scxi-1175; ni scxi-1190; ni scxi-1191; ni scxi-1192; ni scxi-1193; ni scxi-1194; ni scxi-1195; ni scxi-1314t; ni scxi-1502; ni scxi-1503; ni scxi-1520; ni scxi-1521/b;. 1支持下列操作系统: Windows 10(32位和64位) Windows 8. 1 /7 SP1 (32ビットおよび64ビット. com. SCXI-1162HV User Manual - National Instruments. 3500/93 135799-01 Mechanical protection system, BENTLY NEVADA, 3500/93 135799-01 Mechanical protection system Brand: BENTLY NEVADA Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import origin: United States. I know that both 11. GE General Electric DS200CPCAG1ABB Gas Turbine Card IN STOCK NI SCXI-1162HV Optical Isolation Digital Input Module from the United States Powerfully Supplied GE General IS200EROCH1ABB Inventory. Categories: NI. The optical isolation eliminates ground-loop problems. The terminals labeled GND are not used on the SCXI-1162. The terminal block has 48 screw terminals for easy signal connections. 1 Readme. Supported Operating Systems. Part Number: 182638-01, 182638C-01, 182638E-01, 185628C-01, 182628E-01, 182638D-01, 776572-62H The SCXI-1162HV is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. SCXI-1162HV User Manual - National Instruments. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. for any updates to the current NI-DAQmx readme. SCXI-1162HV NI module, NI, SCXI-1162HV NI module Brand: National Instruments Name: Module Current: 5A Voltage: 24V Mode of use: Hot plug implementation standard: Import. Supported Operating Systems. +5 to +10 V Digital Logic Levels for the SCXI-1162 Digital logic levels for the SCXI-1162HVWith the SCXI-1162HV, the Vcc terminal remain unused, the GND terminal is used for ground reference, and the CH(X) terminal is used for the input signal. SCXI™ Getting Started with SCXI. 07-16-2018 11:58 AM. This scxi 1001 has 5x scxi 1163R modules and 2x scxi 1162HV modules. SCXI-1162HV Front Connector; SCXI-1162HV Rear Connector with W2 Jumper in PAR Position; SCXI-1162HV Rear Connector with W2 Jumper in SER Position; SCXI-1163 Front Connector; SCXI-1163 Rear Connector with W6 Jumper in P Position; SCXI-1163 Rear Connector with W6 Jumper in S Position; SCXI-1346 Shielded Multichassis Cable. The module is programmed by the DAQ device serially over the SCXIbus. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B Ð High-voltage 250 VDC TBX-1328 SCXI-1120, SCXI-1120D, SCXI-1121,SCXI-1125, SCXI-1126 SH32-32-A Sockets for current. EN. The terminal block has 48 screw terminals for easy signal connections. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. It is an ideal solution for large-channel-count temperature or voltage applications. About This Manual. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01ni scxi-1600 usbモジュール 重要なお知らせ: USB DAQデバイスおよびWindows XP用Microsoft Hotfix Windows XPにNI-DAQmxをインストールしてUSB DAQデバイスを使用する場合は、 技術サポートデータベース(969238) に記載されているMicrosoft Hotfixをインストールすることをお勧めし. 0不再支持Microsoft Windows 7 RTM、Windows Vista、Windows XP和Windows Server 2003. SCXI-1162HV. 6. 1 and 8. ¥ 668. SCXI™ Getting Started with SCXI. SCXI-1162HV PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs -. Warning: The TBX-1326 and SH48-48-B limit the maximum working common-mode voltage between banks or between banks and earth ground to 250 V rms maximum. 1. . 0 adds support for LabVIEW 2016. 5 adds support for LabVIEW NXG 2. The TBX-1326 mounts on most European standard DIN EN mounting rails. 1. This module is controlled by the DAQ device serially in multiplexed-mode over the SCXIbus making it easy to integrate multiple modules into existing SCXI systems without additional DAQ devices or cabling. NI-DAQmx 17. S. 2016年起NI-DAQmx将不再支持Microsoft Windows Vista、Windows XP和Windows Server 2003. For example, you can use an SCXI. connections to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules. com. 1は、イーサネットおよびワイヤレスCompactDAQシャーシ上のNI-XNETモジュールが正しくロードされない問題を. Calibration for SCXI devices is supported only in Traditional NI-DAQ. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01I/O Systems National Instruments SCXI-1162HV User Manual. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. . The National. National Instruments SCXI-1127- 30 W, 60 VA maximum switching power for each channel. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Spare parts experts in the field of industrial automation. SCXI-1162HV User Manual - National Instruments. 308 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ [email protected], General-Purpose Switch Module for SCXI —The SCXI‑1161 is a general-purpose switching module with independent single‑pole double‑throw (SPDT), also called Form C, latching relays with very low on-resistance and low thermal offset. 8-Channel Isolated, ±300 VDC, 10 kHz Filter, Voltage Input Module for SCXI —The SCXI‑1125 is designed for the signal conditioning and isolation of thermocouple, millivolt, volt, and current signals. Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. The terminals labeled VCC on the SCXI-1326 terminal block are not used with the SCXI-1162HV or the SCXI-1163R. We have a great online selection at the lowest prices with Fast & Free shipping on many items!SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01NI工程師你好,我想問一下關於OVDER TRACKING的一些相關的東西 我是初學者有沒有一些範例能參考看看。我們是用LABVIEW7. All prices are shown in USD. SCXI Terminal Blocks 3 BUY ONLINE at ni. 0では、以下のオペレーティングシステムがサポートされます。. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. According to the the SCXI-1162HV User Manual "Only DIO DAQ boards can read the data from the SCXI-1162HV in parallel mode; MIO boards can only read from the SCXI. Digital Input Number of channels. National Instruments will, at its option, repair or SCXI-1162HV PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, INPUT MODULE, DIGITAL 32 CHANNEL, HIGH VOLTAGE ISOLATED, 240 VAC/DC, DIGITAL, PROGRAMMED BY THE DAQ DEVICE SERIALLY OVER THE SCXIBUS The SCXI-1162HV senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals. 1 1 (32位和64位); Windows 7 SP1 2 (32位和64位); Windows Embedded Standard 7 2 、SP1(32位和64位); Windows Server 2012 R2 1 (64位); Windows Server 2008 R2 1 、SP1(64位,不支持Server Core Role); 1 NI软件安装VC2015运行引擎和. NI Software Support for Microsoft Windows 7, Windows Vista, Windows XP, and Windows Server 2003. All terminals of the NI TBX-1326 are used when it is coupled with the SCXI-1163. SCXI-1162HV. National Instruments SCXI-1163R 32-Channel Optically Isolated Solid-State Relay Switch. English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian česk. The NI SCXI-1326 (Part Number: 777687-26) is a High-Voltage Screw Terminal Block with supports to link to the SCXI-1162, SCXI-1162HV, SCXI-1163, and SCXI-1163R modules’ front connector. +86-17735379951SCXI-1162HV User Manual - National Instruments. 32-Channel, Input (240 V), Digital I/O Module for SCXI —The SCXI‑1162HV is an optically isolated digital input module for SCXI. When you use an NI 6025E with an SH1006868 cable, the I/O signals appear on two 68-pin connector. The. SCXI-1162HV, SCXI-1163, SCXI-1163R SH48-48-B – High-voltage 250 VDC TBX-1328 SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126 SH32-32-A Sockets for current input resistors. These signals. 1 /7 SP1 (32ビットおよび64ビット. 以下は、NI-DAQmx 17. The official life cycle status of the NI SCXI-1162HV has been stated as “Obsolete” according to National Instruments. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01In SCXI slots we are using SCXI 1125 with SCXI 1327 connector block, SCXI 1162HV with SCXI 1326 connector block and SCXI 1169. 3. " SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01 With the SCXI-1162HV less than 1VAC is guaranteed to be a 0 and greater than 10VAC is guaranteed to be a 1. info and type rdfis5 to order a configured PXI/SCXI combination chassis. Call. 它有一个 2 hz截止频率滤波器 scxi-1127scxi-1140 scxi-1141scxi-1143 scxi-1162scxi-1162hv scxi-1163scxi-1163r scxi-1180scxi-1190 scxi-1192scxi-1193 scxi-1300scxi-1302 scxi-1325scxi-1326 产品广泛应用于电厂、造纸、钢铁、矿场、石油、橡胶、供水、水泥、化工、玻璃 印刷、纺织、机械、塑料、涂料. Academic and Research; Aerospace, Defense, and Government;. com or CALL 800 813 3693 (U. SCXI-1162HV: 32. The NI SCXI-1162 (Part Number: 776572-62) is an optically isolated Digital Input Module, which can interface to field digital logic signals where common-mode voltages may exist, such as TTL and CMOS. The SCXI-1162HV senses the presence of a wide range of AC or DC signals, from digital logic level signals up to 240 VAC/VDC signals. このファイルには、インストール手順、既知の問題など、NI-DAQmxに関する重要な情報が記載されています。. 1 1 /7 SP1 2 (32-bit 3 and 64-bit); Windows Embedded Standard 7 2 SP1 (on CompactDAQ and IC-317x controllers); Windows Server 2012 R2 1 (64-bit); Windows Server 2008 R2 1 SP1 (64-bit, not supported on Server Core Role); 1 NI. Caution If you plug the unmodified SCC-FT01 into any SCC socket other than single-stage AI (sockets J1 through J8) or AO (sockets J17 and J18), you can damage the E Series DAQ device. 6. It is an ideal solution for large-channel-count temperature or voltage applications. The following operating systems are supported by NI-DAQmx 18. 2를 설치합니다. El SCXI‑1162HV también puede operar en modo paralelo cuando se cablea directamente a un dispositivo de E/S digital. These relays are suitable for switching, routing, and controlling medium-level signals. ni scxi-1600 usb模块. . This chapter also includes specifications and connection instructions for the signals on the SCXI-1122 connectors. NI-DAQmx 16. SCXI-1162HV Digital I/O module , SCXI-1162HV module Product Features Estimated lead time: 1-3 days ① Brand: NI ② Model: SCXI-1162HV ③ Product category: module ④ Payment method: T/T, USD, Western Union ⑤ Freight: The freight in different regions shall be borne by the local freight forwarder. TBX-1326 high-voltage terminal block with the SCXI-1162/HV, SCXI-1163, and SCXI-1163R modules. 5. 01 and NI. NET 4.